This command sets the minimum time between consecutive CSNP transmissions on the specified interface.
vlan all | Applies the timer configuration to all IS-IS VLANs. |
vlan_name | Specifies a single VLAN to which the timer configuration applies. |
seconds | Sets the timer interval. The range is 1 to 65535 seconds. |
level [1 | 2] | Limits the configuration to either level 1 or level 2. If neither level 1 nor level 2 is specified, the configuration applies to both levels. |
10 seconds.
Periodic CSNPs are only sent on broadcast interfaces and only by the DIS.
The following command sets the CSNP interval time for all IS-IS VLANs to 15 seconds:
configure isis vlan all timer csnp-interval 15
This command was first available in ExtremeXOS 12.1.
This command is available on platforms with a Premier license as described in the Switch Engine v33.1.1 Licensing Guide document.